Nimonic 75 Stud Bolts
ASME B18.31.2BS HR 5
Nimonic 75 stud bolts pair a solid-solution nickel-chromium alloy with double-ended anchoring for furnace shields, burner mounts, and retort covers under repeated heating and thermal cycling. The alloy resists scaling at joint faces.
- MOQ
- 100PCS
- Samples · typical
- ~20 days
- Production · typical
- 25–35 days
- Heat treatment
- Annealed
EN 10204 3.1 MTC + heat-number traceability
Which standard is on your order?
Raw Material Specifications
Threads · Metric
Threads · Inch
Dimension Reference
Heat Treatment
AnnealedAnnealing reduces work hardening and restores ductility for the specified supplied condition.
What we can make in Nimonic 75
Fully threaded
Two nuts clamp the flange or cover; usable thread length spans the assembled grip.
Double-end
A plain centre spans the grip, with a threaded portion at each end for the nuts.
Tap-end
One end engages a tapped casing; the exposed end accepts the cover nut.
- Threads
- Metric · UNC · UNF · 8UN · UNJ
- Forms
- Continuous thread · Double-end · Tap-end
- Final condition
- Annealed
- Inspection
- Thread size and fit; overall and effective thread length; end geometry; lot identification.
Manufacturing route
CNC machining suits samples and special end forms. Repeat lots use cut-to-length stock with rolling or cutting selected for the ordered thread and material condition.
Heat treatment & final condition
The ordered annealed or solution-treated state is retained in the lot record; forming and machining do not replace the specified thermal condition.
Finished geometry
End lengths, runout and effective thread engagement are checked separately from overall length; tap ends are gauged to their own fit requirement.
Where Nimonic 75 fits — and what matters

Burner mounts & nozzles
Nimonic 75 Stud BoltsNimonic 75 studs suit moderately loaded burner brackets and small mounting plates exposed to heat and oxidation. They provide fastening points that can stay installed while the accessible nuts and bracket are removed for burner maintenance.
Connection requirements
- Mount joint thickness, gasket type, and required preload
- Stud diameter, overall length, and nut engagement at each end
- Temperature range, cycling duty, and heat-number certification

Heat shields & furnace linings
Nimonic 75 Stud BoltsStuds through insulation or stand-offs let shield retainers be secured away from the furnace structure. Nimonic 75 resists oxidation and scaling at the exposed hot portions. Its moderate-strength profile suits retaining and support duties where the main requirement is a serviceable heat-resistant attachment.
Connection requirements
- Panel and lining thickness, and required preload
- Stud diameter, overall length, and nut engagement at each end
- Temperature range, cycling duty, and heat-number certification

Retort & muffle covers
Nimonic 75 Stud BoltsOn lightly loaded retort covers and auxiliary plates, Nimonic 75 studs guide the part into position and accept nuts outside the cover. Oxidation resistance supports repeated furnace exposure. The stud form is especially useful when the mounting points should remain undisturbed during routine opening.
Connection requirements
- Cover joint thickness, gasket type, and required preload
- Stud diameter, overall length, and nut engagement at each end
- Temperature range, cycling duty, and heat-number certification
Same stud. Different material priorities.
Nimonic 75 material dataInconel 601 Stud Bolts
Inconel 601 studs provide fixed, oxidation-resistant mounting points for furnace covers, lining retainers and hot-side supports. Nuts can be removed while the stud stays installed. Projection and stand-off length help place the accessible nut away from the hot attachment point.
Inconel 600 Stud Bolts
Inconel 600 studs provide fixed attachment points on lining supports, hot accessory covers and selected caustic-service equipment. Heat and corrosion resistance are useful at exposed shanks and thread ends. Removable nuts allow access without repeatedly withdrawing body-mounted fasteners.
Nimonic 80A Stud Bolts
Nimonic 80A studs carry hot tensile loads at selected valve bonnets, boiler supports and exchanger covers. Precipitation hardening supplies nickel-alloy strength at temperature. Accessible end nuts provide cover removal or support adjustment without requiring the stud itself to turn with every maintenance operation.
From drawing to documented delivery




- 01Drawing & BOMForm, dimensions and quantity
- 02Material & formingGrade, heat and manufacturing route
- 03Final inspectionGeometry, threads and ordered tests
- 04Documents & dispatchLot records and identified packing
Order documents
- Material identity
- UNS N06075 · heat number · ordered condition
- Final-part acceptance
- Grade chemistry, supplied condition and ordered mechanical requirements.
- Dimensional record
- Thread size and fit; overall and effective thread length; end geometry; lot identification.
- Traceability
- EN 10204 3.1 material certificate · production lot · identified packing
Matching Kit
Flange Stud Bolt KitsBuild your Nimonic 75 stud enquiry
Questions about Nimonic 75 stud bolts & threaded rods
Does changing the stud alloy also change the nut selection?
The nut needs compatible internal threads, sufficient engaged height and a specified material condition. Select lubricant or surface treatment with the stud–nut pair, because assembly friction affects the preload obtained from tightening.