UNS N06075 · W.Nr. 2.4951

Nimonic 75 Double-end studs

ASME B18.31.2BS HR 5

A Nimonic 75 double-end stud leaves the installed end in the equipment body while the service nut is removed. Its oxidation resistance in heat-processing equipment must cover the trapped body-end interface as well as the exposed end.

MOQ
100PCS
Samples · typical
~20 days
Production · typical
25–35 days
Heat treatment
Annealed

EN 10204 3.1 MTC + heat-number traceability

Upload drawing
Other alloys800HT718A-286310S

Which standard is on your order?

Raw Material Specifications

Threads · Metric

Threads · Inch

Dimension Reference

Heat Treatment

Annealed

Annealing reduces work hardening and restores ductility for the specified supplied condition.

What we can make in Nimonic 75

Clamping stud: two threaded ends with a plain shank

Clamping stud

Use for through-bolted covers and housings with access to both nuts. The plain grip spans the joint; independently sized threaded ends accommodate unequal nut-side clearances.

Tap-end stud: unequal threaded ends

Tap-end stud

Use on valve bonnets and machine housings opened repeatedly for maintenance. The insertion end remains in the body while the outer nut is removed, reducing repeated wear of the housing thread.

Thread systems
Metric · UNC · UNF · 8UN · UNJ
Geometry
Two threaded ends · Plain shank
Assembly
Nut-to-nut · Tap-end
Final condition
Annealed
Inspection
End thread lengths · Shank diameter · Thread gauging

Manufacturing route

CNC machining suits samples and special end forms. Repeat lots use cut-to-length stock with rolling or cutting selected for the ordered thread and material condition.

Heat treatment & final condition

The ordered annealed or solution-treated state is retained in the lot record; forming and machining do not replace the specified thermal condition.

Finished geometry

End lengths, runout and effective thread engagement are checked separately from overall length; tap ends are gauged to their own fit requirement.

Where Nimonic 75 fits — and what matters

Heat-treatment workshop with horizontal furnaces, green pipes and a blue motor

Furnaces & Heat Treatment

Retort and furnace-access covers

Nimonic 75 double-end studs connect retort and furnace-access covers through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Hot dwell, thermal expansion and repeated furnace cycles set the working load.

Body-end engagement · nut-end length · shank fit
Furnaces & Heat Treatment fasteners
Technician inspecting blade rows beneath a large turbine rotor

Power & Turbines

Hot-gas access covers and inspection closures

Nimonic 75 double-end studs connect hot-gas access covers and inspection closures through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Hot dwell and start-stop expansion act on the supported or moving component.

Body-end engagement · nut-end length · shank fit
Power & Turbines fasteners
Silver distillation columns with access ladders and yellow service platforms

Chemical Processing

Reformer access covers and hot-gas inspection closures

Nimonic 75 double-end studs connect reformer access covers and hot-gas inspection closures through a threaded body end and an accessible nut end. The plain shank spans the cover grip. These parts work in the heated equipment zone, where sustained loading and thermal expansion govern their section and clearance.

Body-end engagement · nut-end length · shank fit
Chemical Processing fasteners

Same double-end stud. Different material priorities.

Nimonic 75 material data
UNS N08811

Incoloy 800HT

Tightly controlled carbon and Al + Ti for creep duty.

Connection priority
Tension through the grip and load transfer into the housing
N08811 material control
800HT tightens the 800-family chemistry around creep performance. Its solution-treated, coarse-grain condition and N08811 identity should remain linked through forming and final acceptance. At the body-end thread inside the tapped housing, the relevant metal temperature can differ from the process or furnace set point.
Incoloy 800HT double-end studs
UNS N07718

Inconel 718

Precipitation-hardened strength for compact, highly loaded connections.

Connection priority
Tension through the grip and load transfer into the housing
Strength after aging
Machine-stock properties and final aged properties describe different states. The final heat-treatment lot and mechanical results establish the strength available in the installed part. At the body-end thread inside the tapped housing, the relevant metal temperature can differ from the process or furnace set point.
Inconel 718 double-end studs
UNS S66286

A-286

Aged iron–nickel alloy strength for hot bolting.

Connection priority
Tension through the grip and load transfer into the housing
Grade 660 class
An ASTM A453 Grade 660 order includes its class and corresponding processing requirements. The alloy name A-286 alone does not identify that acceptance condition. At the body-end thread inside the tapped housing, the relevant metal temperature can differ from the process or furnace set point.
A-286 double-end studs

From drawing to documented delivery

Heat treatment
Heat treatment
CNC machining
CNC machining
Rockwell hardness testing
Rockwell hardness testing
Wooden-crate packing
Wooden-crate packing
  1. 01Drawing & BOMForm, dimensions and quantity
  2. 02Material & formingGrade, heat and manufacturing route
  3. 03Final inspectionGeometry, threads and ordered tests
  4. 04Documents & dispatchLot records and identified packing

Order documents

Material identity
UNS N06075 · heat number · ordered condition
Final-part acceptance
Grade chemistry, supplied condition and ordered mechanical requirements.
Dimensional record
End thread lengths · Shank diameter · Thread gauging
Traceability
EN 10204 3.1 material certificate · production lot · identified packing

Build your Nimonic 75 double-end stud enquiry

QUOTE LIST ITEMNimonic 75 double-end studs; UNS N06075; Equal-end clamping stud

Questions about Nimonic 75 double-end studs

Can both ends use the same thread designation?

They can, but the body end may require a different fit or engagement from the nut end. Record each end separately, including a different pitch or interference requirement where the equipment drawing uses one.

Technical references & photo credits