Technician inspecting blade rows beneath a large turbine rotor

High-temperature fasteners for Turbines & Power Plants.

High-strength casing studs, compact flange bolts and hot-service replacements for turbine and power-plant maintenance.

EN 10204 3.1 MTCHeat traceabilityMechanical test resultsPMI testing available

Which fasteners fit your turbine and power-plant applications?

BYBOLT supplies Inconel 718 stud bolts for high-strength turbine-casing joints and A-286 12-point flange bolts where wrench access is tight. Inconel 718 double-end studs secure steam-valve bonnets, while Incoloy 800H stud bolts resist creep in sustained hot service. Order to your equipment drawing, with the required heat treatment and mating nuts.

Fasteners for turbines & power-plant equipment.

Steam turbine casing with bolted horizontal split-line joints and a bearing housing in a turbine hall.

Gas & steam turbine casing joints

A turbine casing stud must carry tension over long hot operating periods and still permit casing access at overhaul. X-750 combines the stud arrangement with precipitation-hardened elevated-temperature properties. Its treatment condition is selected around the actual temperature and load duration of the bolted joint.

Inconel X-750 Stud Bolts
Connection requirements
  • Casing joint thickness, gasket type, and required preload
  • Stud diameter, overall length, and nut engagement at each end
  • Temperature range, cycling duty, and heat-number certification
Steam globe valve with a bolted bonnet, flanged connections and an electric actuator in a maintenance workshop.

High-pressure steam valve bonnets

Inconel X-750 studs clamp hot steam-valve bonnets through accessible nuts. Their precipitation treatment is chosen for the temperature and duration of loading, so the stud's hot strength matches the operating duty. On tapped-stud bonnets, the cover lifts off after the nuts are removed while the studs remain in the valve body.

Inconel X-750 Stud Bolts
Connection requirements
  • Bonnet joint thickness, gasket type, and required preload
  • Stud diameter, overall length, and nut engagement at each end
  • Temperature range, cycling duty, and heat-number certification
Generator exhaust pipe with a metal expansion bellows, bolted flanges and insulated upper ductwork.

Exhaust manifolds & expansion bellows

At an exhaust flange or bellows support, Inconel 718 hex bolts carry pipework loads through a limited bolt pattern. Precipitation-hardened strength is useful where the fasteners remain hot and there is little room to increase their diameter. Accessible heads allow the complete bolts to be withdrawn when the flange or support is dismantled.

Inconel 718 Hex Bolts
Connection requirements
  • Manifold flange thickness, gasket type, and required preload
  • Bolt diameter, grip length, and nut/washer stack-up at installed position
  • Temperature range, vibration duty, and age-hardened condition certification
Boiler tube banks suspended from overhead supports inside an open maintenance access hatch.

Boiler tube hangers & superheaters

On boiler hanger and superheater support rods, X-750 nuts can form part of a sustained hot-load attachment. The regular hex pattern fits compact brackets and allows position adjustment on threaded ends. The relevant advantage is the alloy's hot mechanical behaviour in the specified treatment condition.

Inconel X-750 Hex Nuts
Connection requirements
  • Mating bolt diameter, thread form, and thread class
  • Nut height, width across flats, and bearing-face condition required
  • Temperature range, cycling duty, and heat-number certification
Large flue duct with a bolted expansion joint entering a power-plant tower within a steel support structure.

Flue-gas desulfurization (FGD) ducts

At FGD duct covers and inspection doors, fasteners may see acidic condensate concentrated beneath deposits. Inconel 625 hex bolts provide chloride-corrosion resistance at the head, shank and thread. The removable bolt form suits panels opened for cleaning, where corrosion of the fastening points would complicate maintenance.

Inconel 625 Hex Bolts
Connection requirements
  • Duct joint thickness, gasket type, and required preload
  • Bolt diameter, grip length, and nut/washer stack-up at installed position
  • Chloride and acid exposure, and heat-number certification
Large generator rotor with a shaft coupling flange supported on maintenance stands in a workshop.

Generator & rotor tie-bolt assemblies

On generator and rotor tie connections, X-750 studs can serve a sustained axial load path in a heat-resistant alloy. End nuts allow the assembly load to be applied without rotating the stud. These components follow the rotor drawing's end geometry and retention details as well as its material condition.

Inconel X-750 Stud Bolts
Connection requirements
  • Assembly joint thickness, gasket type, and required preload
  • Stud diameter, overall length, and nut engagement at each end
  • Temperature range, cyclic duty, and heat-number certification

Temperature, expansion, and condensate corrosion.

B16, A-286, 718 and Waspaloy serve different hot-bolting duties. For a casing joint, compare temperature-specific relaxation and creep data in the final heat-treated condition; room-temperature strength does not establish retained clamp load.

What to specify
  • Design service temperature band
  • Required clamp-load retention criterion
  • Creep strength grade designation
Insulated steam turbine casings with an exposed bolted flange and maintenance platforms in a power-plant turbine hall.

Insulated steam turbine casings with an exposed bolted flange and maintenance platforms in a power-plant turbine hall.

Compare power-plant fastener alloys.

Power & Turbines: material grade, primary duty, environment, relative material cost and fastener forms
Material gradeMechanical Duty / FocusEnvironmentRelative
cost
Popular
fastener forms
Inconel 718UNS N07718Age hardened
Hot casing joints with startup and shutdown cycles$$$Stud bolts
A-286UNS S66286Hot strength
Hot casing and steam-system connections$$12-point bolts
Incoloy 800HUNS N08810Creep resistance
Hot exhaust and heat-recovery equipment with long dwell times$$$Stud bolts
Inconel 625UNS N06625Corrosion resistance
Seawater-cooled auxiliaries and corrosive condensate exposure$$$Stud bolts

Budget guide: $ lower · $$ moderate · $$$ higher · $$$$ premium. Relative raw-material bands; dimensions, quantity, processing and inspection determine the finished-fastener quote.

Material & cost references

Cost bands group overlapping published supplier ranges for initial budgeting; they are not live BYBOLT prices. Specify the exact UNS and final condition on the order.

Turbine casing bolts & steam-valve studs.

Inconel 718 stud bolts product arrangement

Inconel 718 stud bolts

Provide high-strength clamping at hot turbine casings, with grip and thread lengths matched to the joint.

Turbine & steam-valve maintenance kits.

Group the hardware for each casing or valve before the outage, including the short bolts and mating nuts that are easy to miss.

Power-plant fastener traceability & inspection.

EN 10204 3.1 MTC, heat traceability and mechanical test results with each shipment. Add the tests your equipment specification requires.

Brinell hardness testing machine with specimen anvil
Brinell hardness testing

Material identity

Match the ordered grade and material heat to the certificate, part identification and packing list.

Final condition

Link the specified processing condition and mechanical results to the finished batch; keep separate heat-treatment batches identifiable.

Drawing dimensions

OEM part number, drawing revision and installation location.

OEM acceptance

Include hot tensile, creep, relaxation or witness requirements from the controlled equipment specification.

See the certificate and inspection guide

Before you order power-plant fasteners.

Send the drawing and the service details for your connection. We can quote the specified parts, finish and inspection package together.

Get a Quote
Can you quote an OEM replacement from a part number?

Send the part number with the controlled drawing or dimensional specification, alloy condition and quantity. Include any inspection requirements attached to the OEM purchase specification.

Can room-temperature test results cover a hot joint?

Room-temperature tests document those measured properties. If the design requires hot tensile, creep or relaxation evidence, include the test temperature, duration and acceptance criteria in the enquiry.

Can nuts and studs be supplied as matched sets?

Yes. Specify both components, including their material conditions and nut pattern. Sets can be identified by casing or valve tag and linked to their material and finished-batch records.

YOUR COMPLETE BOLTING PACKAGE

Send your drawing
or parts list.

Upload the drawing or BOM with its revision. We quote the material, dimensions, quantities and inspection requirements for your equipment.

OEM drawing/part number, casing or valve tag, alloy condition, metal temperature, grip/thread dimensions and outage quantity…

Bolting list and contact details

Drop your bolting list or drawing here

PDF, XLSX, CSV, DWG, DXF, STEP & images

Up to 10 files · 20 MB each · 100 MB total

Files are sent only when you submit.