A support bracket at the turbine flange, a liner pin in the transition duct and a cover bolt near the stack all sit in the same gas flow, yet they fail for completely different reasons.

Gas temperature by position, not one number
The EPA's catalog of CHP technologies puts gas-turbine exhaust at up to 800–900°F (about 427–482°C) for smaller industrial machines and up to 1,100°F (about 593°C) for some large utility and aeroderivative units. Newer heavy-frame machines exhaust at about 600°C or more. A duct burner can raise the gas temperature ahead of the superheater well above turbine exhaust, and each boiler section downstream takes heat out, so the bolt temperature is a property of its position.
For each attachment, the enquiry should give the gas temperature at that point, whether the bolt sits in the gas stream, behind a liner or on the outer casing, and whether the temperature is steady or follows turbine load. A unit that cycles daily puts its hot-end bolts through hundreds of heat-ups a year, which matters for scale life as much as for creep.
Load-bearing bolts and shielding fasteners are different jobs
A load-bearing bolt holds weight, pressure or vibration for the life of the plant. At HRSG inlet temperatures, creep slowly stretches a loaded bolt, and relaxation lowers its preload hour by hour. These bolts need enough strength to hold preload, an alloy that keeps it at temperature, and a check of preload loss at temperature over the design life, plus a measured stretch or preload check at major outages.
A shielding fastener holds a liner plate, cover or insulation panel. It carries little load, so creep strength hardly matters, but it lives in the hottest, most oxidizing spot and has to let the plate move. What it needs is scale resistance, the right washer and a clearance that works hot.
Mark each position on the drawing as load-bearing or shielding, with the load for the first group. A set list that doesn't separate the two can't be checked at receipt, and after a failure nobody can tell which job the failed bolt was doing.
Movement: fixed points, sliding joints and liner fasteners
Every part of the duct grows as it heats, and the growth adds up along its length. For a rough sense of scale, 10 m of steel heated by 500°C with an expansion coefficient of about 13 µm/m·K grows by 65 mm. That movement has to go into a sliding support, an expansion joint or a designed clearance; otherwise it bends the duct, shears bolts or cracks the casing.
Internally insulated ducts add a twist. The liner plates run hot while the outer casing, behind the insulation, stays cool, so the liner grows against a casing that barely moves. Liner fasteners therefore have to let the plate slide, usually through slotted or oversized holes with a large washer, rather than clamping it. A liner bolt tightened like a structural bolt either shears or tears through the plate within a few cycles.
In such ducts the load-bearing supports usually sit on the cool casing side, so the hottest bolts are often the lightly loaded liner fasteners. The drawing should show the fixed points, the movement direction at each position, which joints clamp and which slide, and the hot clearance for each sliding joint. The bolt can only be specified once that is settled.
Alloy by job and temperature
| Candidate | UNS and specification | Where it fits on the exhaust path | What to watch |
|---|---|---|---|
| Inconel 718 | N07718, ASTM B637 / AMS 5663 aged | Load-bearing joints that must hold high preload, up to about 650°C | Aged condition proved on the certificate |
| A286 | S66286, ASTM A453 Grade 660 | Load-bearing joints below about 540°C | Expansion above a ferritic casing; class on the order |
| Incoloy 800H | N08810, ASTM B408 | Hot attachments where creep life matters more than high preload | Low yield (170 MPa minimum); carbon, grain size and anneal on the certificate |
| 321 / 347 | S32100 / S34700, ASTM A479 | Liner pins, shields and covers in the moderate zones | Shielding duty, not sustained hot load |
| 310S | S31008, ASTM A479 | Shield fasteners in the hottest zones, around duct burners | Slight embrittlement in continuous service at 600–900°C |
For local heat shielding, see 310S long-shank bolts for furnace heat shields and the 310S long-shank hex-head bolt option.
Related references: Inconel 718 · A286 · Incoloy 800H · 321 · 347 · 310S
For load-bearing joints, the choice depends on how much preload the joint needs and how hot it runs. Aged 718 keeps most of its strength through the HRSG range and is the usual answer where a hot joint must stay tight; A286 does the same job at lower cost where the joint stays below about 540°C. Incoloy 800H is a creep-resistant alloy rather than a high-strength one: ASTM B408 sets its room-temperature minimums at 450 MPa tensile and 170 MPa yield, and the Special Metals 800H/800HT bulletin gives the creep and rupture data that justify it above about 650°C. 800H hex bolts suit hot brackets and frames where the load is modest.
For shielding, 321 and 347 are stabilized against sensitization and hold their scale well at moderate exhaust temperatures. Near duct burners, where gas runs hotter, 310S is the economical step up; Outokumpu's Therma datasheet suggests it for use up to about 1050°C in air and notes slight embrittlement in long service between 600 and 900°C. Inconel 601 is worth its price only where shields cycle hard, as our furnace burner article explains for a similar problem.
Heads, washers and what to look for at outages
Head and washer follow from the job. Load-bearing joints take a hex head and a flat washer sized for the bearing face. Liner fasteners need a washer large enough to cover the slot through the full movement, and a head or nut that can be reached at outages. Give the head type, washer diameter and tool space at each position.
At a major outage, compare removed bolts by position. Permanent stretch on load-bearing bolts at the hot end points to creep, so the alloy or the load assumption needs review. Sheared or bent liner fasteners point to movement that the slot or clearance didn't allow. Scale loss concentrated near a burner points to local gas temperature.
| Lock before ordering | Why it matters | Document to ask for |
|---|---|---|
| Gas temperature at each position | The hot end and the stack end need different alloys | Gas path drawing with temperatures |
| Load-bearing or shielding, load per position | Creep governs one, oxidation and movement the other | Position map and loads |
| Fixed points, movement direction, slide or clamp | A clamped liner shears or tears out | Fixed-point layout, movement calculation |
| Washer size and slot length for sliding joints | The washer must cover the slot through full travel | Liner fastener detail |
| Traceability by position | A failed bolt must be traceable to its job and heat | Set list, EN 10204 3.1 certificates, PMI where specified |
Related references: EN 10204 3.1 certificates
Requesting a quote
An enquiry the team can act on looks like this: "M16 Inconel 718 bolts for in-gas support brackets on an uninsulated HRSG inlet section, about 590°C, load-bearing, 48 per unit; plus M12 321 liner studs with 60 mm washers for the transition duct, slotted holes per drawing." A photo of a removed liner fastener or a stretched support bolt helps tell creep from movement damage.
With the gas path drawing and the position map, the engineering team can confirm the alloy for each job and quote the full set with EN 10204 3.1 certificates. For other boiler and turbine bolting, see power generation and turbines.