
430 Double-end studs
ASME B18.31.2
A 430 double-end stud leaves the installed end in the equipment body while the service nut is removed. Its ferritic stainless performance for mild industrial exposure must cover the trapped body-end interface as well as the exposed end.
- MOQ
- 100PCS
- Samples · typical
- ~20 days
- Production · typical
- 25–35 days
- Heat treatment
- Annealed
EN 10204 3.1 MTC + heat-number traceability
Which standard is on your order?
Raw Material Specifications
Finished-Stud Specifications
Threads · Metric
Threads · Inch
Dimension Reference
Heat Treatment
AnnealedAnnealing reduces work hardening and restores ductility for the specified supplied condition.
What we can make in 430
Clamping stud
Use for through-bolted covers and housings with access to both nuts. The plain grip spans the joint; independently sized threaded ends accommodate unequal nut-side clearances.
Tap-end stud
Use on valve bonnets and machine housings opened repeatedly for maintenance. The insertion end remains in the body while the outer nut is removed, reducing repeated wear of the housing thread.
- Thread systems
- Metric · UNC · UNF · 8UN · UNJ
- Geometry
- Two threaded ends · Plain shank
- Assembly
- Nut-to-nut · Tap-end
- Final condition
- Annealed
- Inspection
- End thread lengths · Shank diameter · Thread gauging
Manufacturing route
CNC machining suits samples and special end forms. Repeat lots use cut-to-length stock with rolling or cutting selected for the ordered thread and material condition.
Heat treatment & final condition
The final annealed or specified strengthened condition is linked to the lot; an aging treatment is not assumed for a solid-solution alloy.
Finished geometry
End lengths, runout and effective thread engagement are checked separately from overall length; tap ends are gauged to their own fit requirement.
Where 430 fits — and what matters

Industrial Machinery & Automation
Machine housings and service covers430 double-end studs connect machine housings and service covers through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Alignment, operating cycles and replacement access define the working interface.

Automotive & EV Manufacturing Equipment
Test-equipment housings430 double-end studs connect test-equipment housings through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Repeated tooling changes require consistent seating and repeatable assembly dimensions.

Pumps, Valves & OEM
Pump casings and valve bonnets430 double-end studs connect pump casings and valve bonnets through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Repeated maintenance makes fit, engagement and access part of the component specification.
Same double-end stud. Different material priorities.
430 material data316L
Molybdenum-bearing stainless performance in wet equipment.
- Connection priority
- Tension through the grip and load transfer into the housing
- Washdown and retained cleaner
- Cleaner concentration, rinse quality and deposits determine the exposure in covered joints. The low-carbon designation does not independently establish a fastener strength class. Include liquid retained at the body-end thread inside the tapped housing in the exposure description.
17-4 PH
Aging-controlled strength and hardness.
- Connection priority
- Tension through the grip and load transfer into the housing
- H900 versus H1150
- The aging condition changes the balance of strength, hardness and toughness. A replacement part needs the specified H condition, especially where contact wear and shock load occur together.
Inconel 625
Solid-solution strength and resistance to aggressive process liquids.
- Connection priority
- Tension through the grip and load transfer into the housing
- Annealed or solution-annealed 625
- The delivery condition affects strength and high-temperature response. Keep the specified condition with the component’s mechanical acceptance; 718-style aging is not the strengthening route for 625. Include liquid retained at the body-end thread inside the tapped housing in the exposure description.
From drawing to documented delivery




- 01Drawing & BOMForm, dimensions and quantity
- 02Material & formingGrade, heat and manufacturing route
- 03Final inspectionGeometry, threads and ordered tests
- 04Documents & dispatchLot records and identified packing
Order documents
- Material identity
- UNS S43000 · heat number · ordered condition
- Final-part acceptance
- Grade chemistry, supplied condition and ordered mechanical requirements.
- Dimensional record
- End thread lengths · Shank diameter · Thread gauging
- Traceability
- EN 10204 3.1 material certificate · production lot · identified packing
Build your 430 double-end stud enquiry
Questions about 430 double-end studs
Can both ends use the same thread designation?
They can, but the body end may require a different fit or engagement from the nut end. Record each end separately, including a different pitch or interference requirement where the equipment drawing uses one.