17-4 PH Double-end studs
ASME B18.31.2ASTM A564
A 17-4 PH double-end stud leaves the installed end in the equipment body while the service nut is removed. Its aging-controlled strength and hardness must cover the trapped body-end interface as well as the exposed end.
- MOQ
- 100PCS
- Samples · typical
- ~20 days
- Production · typical
- 25–35 days
- Heat treatment
- Solution treated (Condition A) / Age hardened H900 / Age hardened H1025 / Age hardened H1150
EN 10204 3.1 MTC + heat-number traceability
Which standard is on your order?
Raw Material Specifications
Finished-Stud Specifications
Threads · Metric
Threads · Inch
Dimension Reference
Heat Treatment
Solution treated, then aged to the specified H conditionCondition A is the solution-treated starting state; aging to H900, H1025 or H1150 sets the final strength–toughness balance.
What we can make in 17-4 PH
Clamping stud
Use for through-bolted covers and housings with access to both nuts. The plain grip spans the joint; independently sized threaded ends accommodate unequal nut-side clearances.
Tap-end stud
Use on valve bonnets and machine housings opened repeatedly for maintenance. The insertion end remains in the body while the outer nut is removed, reducing repeated wear of the housing thread.
- Thread systems
- Metric · UNC · UNF · 8UN · UNJ
- Geometry
- Two threaded ends · Plain shank
- Assembly
- Nut-to-nut · Tap-end
- Final condition
- Solution treated (Condition A) · Age hardened H900 · Age hardened H1025 · Age hardened H1150
- Inspection
- End thread lengths · Shank diameter · Thread gauging
Manufacturing route
CNC machining suits samples and special end forms. Repeat lots use cut-to-length stock with rolling or cutting selected for the ordered thread and material condition.
Heat treatment & final condition
Solution treatment and the specified aging condition are recorded against the production lot; final dimensions are checked after thermal processing.
Finished geometry
End lengths, runout and effective thread engagement are checked separately from overall length; tap ends are gauged to their own fit requirement.
Where 17-4 PH fits — and what matters

Industrial Machinery & Automation
Machine housings and service covers17-4 PH double-end studs connect machine housings and service covers through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Alignment, operating cycles and replacement access define the working interface.

Automotive & EV Manufacturing Equipment
Test-equipment housings17-4 PH double-end studs connect test-equipment housings through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Repeated tooling changes require consistent seating and repeatable assembly dimensions.

Pumps, Valves & OEM
Pump casings and valve bonnets17-4 PH double-end studs connect pump casings and valve bonnets through a threaded body end and an accessible nut end. The plain shank spans the cover grip. Repeated maintenance makes fit, engagement and access part of the component specification.
Same double-end stud. Different material priorities.
17-4 PH material data316L
Molybdenum-bearing stainless performance in wet equipment.
- Connection priority
- Tension through the grip and load transfer into the housing
- Washdown and retained cleaner
- Cleaner concentration, rinse quality and deposits determine the exposure in covered joints. The low-carbon designation does not independently establish a fastener strength class. Include liquid retained at the body-end thread inside the tapped housing in the exposure description.
Inconel 625
Solid-solution strength and resistance to aggressive process liquids.
- Connection priority
- Tension through the grip and load transfer into the housing
- Annealed or solution-annealed 625
- The delivery condition affects strength and high-temperature response. Keep the specified condition with the component’s mechanical acceptance; 718-style aging is not the strengthening route for 625. Include liquid retained at the body-end thread inside the tapped housing in the exposure description.
Duplex 2205
Duplex strength and chloride-corrosion resistance.
- Connection priority
- Tension through the grip and load transfer into the housing
- S31803 or S32205
- The specified UNS fixes the chemistry. Solution treatment, section size and the ordered mechanical or corrosion tests establish the final duplex condition. Include liquid retained at the body-end thread inside the tapped housing in the exposure description.
From drawing to documented delivery




- 01Drawing & BOMForm, dimensions and quantity
- 02Material & formingGrade, heat and manufacturing route
- 03Final inspectionGeometry, threads and ordered tests
- 04Documents & dispatchLot records and identified packing
Order documents
- Material identity
- UNS S17400 · heat number · ordered condition
- Final-part acceptance
- Lot-linked aging record and mechanical acceptance in the final condition.
- Dimensional record
- End thread lengths · Shank diameter · Thread gauging
- Traceability
- EN 10204 3.1 material certificate · production lot · identified packing
Build your 17-4 PH double-end stud enquiry
Questions about 17-4 PH double-end studs
Can both ends use the same thread designation?
They can, but the body end may require a different fit or engagement from the nut end. Record each end separately, including a different pitch or interference requirement where the equipment drawing uses one.