UNS S32760

Super Duplex S32760 Thin hex nuts

ISO 4035ASTM A276

Limited axial space is the reason to use a Super Duplex S32760 thin nut. Its copper- and tungsten-containing super-duplex performance must be paired with the reduced thread engagement and the intended locking arrangement.

MOQ
100PCS
Samples · typical
~20 days
Production · typical
25–35 days
Heat treatment
Solution annealed and quenched

EN 10204 3.1 MTC + heat-number traceability

Upload drawing

Which standard is on your order?

Raw Material Specifications

Threads · Metric

Threads · Inch

Dimension Reference

Heat Treatment

Solution annealed and rapidly cooled

Solution annealing followed by rapid cooling controls harmful precipitates and preserves the ferrite–austenite structure.

What we can make in Super Duplex S32760

Reduced height hex nut

Reduced-height body

Use in compact adjustment mechanisms and panel assemblies where axial clearance rules out a full-height nut. Check the required proof load against the reduced engagement rather than selecting on clearance alone.

Thin jam nut adjacent to full-height nut

Jam-nut arrangement

Use with a second nut to lock an adjustment on a threaded shaft or linkage. The specified nut order and tightening sequence are part of the locking arrangement, not simply two nuts tightened independently.

Pattern
Thin hex · Jam nut
Key dimensions
Thread · Across flats · Height
Threads
Metric · UNC · UNF
Assembly
Adjusters · Paired nuts
Final condition
Solution annealed and quenched
Inspection
Nut height · Across flats · Thread plug gauging

Manufacturing route

Small lots use machined blanks. Volume nut blanks use a forming route compatible with the alloy before machining the bore and tapping.

Heat treatment & final condition

Solution treatment and cooling control the duplex structure. Subsequent processing must preserve the ordered corrosion and mechanical condition.

Finished geometry

Internal thread gauging, usable engagement and bearing-face alignment are checked after final processing.

Where Super Duplex S32760 fits — and what matters

Ship machinery compartment with green pumps, insulated pipes and pressure gauges

Offshore & Marine

Marine pump shafts and linkage pins

Super Duplex S32760 thin hex nuts serve as jam or retaining nuts on marine pump shafts and linkage pins where axial space is limited. Their reduced thread engagement is part of the retention design. The assembled contact is exposed to saltwater, deposits and neighbouring metals.

Nut thickness · jam arrangement · engagement
Offshore & Marine fasteners
Water-treatment machinery with parallel green pipes, gray pumps and yellow access platforms

Water Treatment & Desalination

Treatment-pump shafts and actuator parts

Super Duplex S32760 thin hex nuts serve as jam or retaining nuts on treatment-pump shafts and actuator parts where axial space is limited. Their reduced thread engagement is part of the retention design. The water stream, cleaning cycle and retained liquid define exposure at the installed part.

Nut thickness · jam arrangement · engagement
Water Treatment & Desalination fasteners
Gas-processing plant with a process tower and twin stacks beyond a cultivated field

Oil & Gas

Valve actuator shafts and linkage pins

Super Duplex S32760 thin hex nuts serve as jam or retaining nuts on valve actuator shafts and linkage pins where axial space is limited. Their reduced thread engagement is part of the retention design. Utility connections and pressure-boundary parts have separate acceptance requirements on the equipment drawing.

Nut thickness · jam arrangement · engagement
Oil & Gas fasteners

Same thin hex nut. Different material priorities.

Super Duplex S32760 material data
UNS N06625

Inconel 625

Solid-solution strength and resistance to aggressive process liquids.

Connection priority
Thread load in a reduced-height body
Annealed or solution-annealed 625
The delivery condition affects strength and high-temperature response. Keep the specified condition with the component’s mechanical acceptance; 718-style aging is not the strengthening route for 625. Include liquid retained at the short internal engagement and paired-nut faces in the exposure description.
Inconel 625 thin hex nuts
UNS S32750

Super Duplex 2507

Super-duplex strength and resistance to chloride pitting.

Connection priority
Thread load in a reduced-height body
Final duplex structure
S32750 chemistry and final solution treatment belong together. Forming, section size and cooling affect the structure represented by the mechanical and corrosion records. Include liquid retained at the short internal engagement and paired-nut faces in the exposure description.
Super Duplex 2507 thin hex nuts
UNS N05500

Monel K-500

Age-hardened strength in the nickel–copper alloy family.

Connection priority
Thread load in a reduced-height body
Strength and hydrogen exposure
K-500 gains strength through aging. Cathodic protection, hydrogen exposure and the ordered condition need joint consideration in highly loaded marine components. Include liquid retained at the short internal engagement and paired-nut faces in the exposure description.
Monel K-500 thin hex nuts

From drawing to documented delivery

Heat treatment
Heat treatment
CNC machining
CNC machining
Rockwell hardness testing
Rockwell hardness testing
Wooden-crate packing
Wooden-crate packing
  1. 01Drawing & BOMForm, dimensions and quantity
  2. 02Material & formingGrade, heat and manufacturing route
  3. 03Final inspectionGeometry, threads and ordered tests
  4. 04Documents & dispatchLot records and identified packing

Order documents

Material identity
UNS S32760 · heat number · ordered condition
Final-part acceptance
Final condition and any ordered phase-balance, corrosion or impact testing.
Dimensional record
Nut height · Across flats · Thread plug gauging
Traceability
EN 10204 3.1 material certificate · production lot · identified packing

Build your Super Duplex S32760 thin hex nut enquiry

QUOTE LIST ITEMSuper Duplex S32760 thin hex nuts; UNS S32760; Thin hex nut

Questions about Super Duplex S32760 thin hex nuts

Can a thin nut replace a regular nut at the same load?

Reduced thread engagement changes stripping capacity. Check the reduced-height nut’s material condition and the intended jam-nut arrangement instead of transferring the regular nut’s load assumption.