UNS N04400 · W.Nr. 2.4360

Monel 400 strip

ASTM B127

Monel 400 strip combines nickel–copper corrosion resistance in seawater and selected chemicals with a thin section for clips, shims and formed parts. Edge condition, temper and rolling direction affect both production feeding and the finished bend.

MOQ
100 kg
Samples · typical
~20 days
Production · typical
25–35 days
Heat treatment
Annealed

EN 10204 3.1 MTC + heat-number traceability

Upload drawing

Which standard is on your order?

Raw Material Specifications

Heat Treatment

Annealed; cold worked for higher strength

Annealing restores ductility after working, while the specified amount of cold work sets higher-strength conditions without aging.

What we can make in Monel 400

Coiled strip

Coiled strip

Use for progressive stamping, spring clips and repeated forming. Strip width, thickness and coil dimensions must suit the tool and feed line to maintain consistent component geometry.

Cut strip length

Cut lengths

Use for short-run brackets, shims and fabricated pieces when coil handling adds unnecessary setup. Flatness and length tolerance help the blank seat consistently in the tool.

Strip camber relative to straight reference

Edge & camber

For narrow stamped or formed parts, control slit-edge burrs to protect tools and contact surfaces. Excess camber pulls the strip away from the intended feed path and affects registration.

Size
Thickness × width
Supply form
Coils · Cut lengths
Edges
Slit · Finished edges
Condition
Grade-specific temper
Final condition
Annealed · Cold worked
Inspection
Cross-section · Surface · Delivery condition · Heat identity

Supply & preparation

Slitting and cut-length preparation follow the requested width, thickness and edge condition. Rolling direction is retained where the forming drawing needs it.

Material condition

The final annealed or specified strengthened condition is linked to the lot; an aging treatment is not assumed for a solid-solution alloy.

Finished geometry

Thickness variation, edge burr, coil set and surface finish determine suitability for the next stamping or forming step.

Where 400 fits — and what matters

Ship machinery compartment with green pumps, insulated pipes and pressure gauges

Offshore & Marine

Seawater pump and cooling-system covers

Monel 400 strip is slit and formed into shims, retaining clips or seal-support pieces around seawater pump and cooling-system covers. Thickness, edge finish and bend direction control the finished fit. The assembled contact is exposed to saltwater, deposits and neighbouring metals.

Thickness tolerance · slit edge · rolling direction
Offshore & Marine fasteners
Water-treatment machinery with parallel green pipes, gray pumps and yellow access platforms

Water Treatment & Desalination

Filter housings and treatment-pump covers

Monel 400 strip is slit and formed into shims, retaining clips or seal-support pieces around filter housings and treatment-pump covers. Thickness, edge finish and bend direction control the finished fit. The water stream, cleaning cycle and retained liquid define exposure at the installed part.

Thickness tolerance · slit edge · rolling direction
Water Treatment & Desalination fasteners
Gas-processing plant with a process tower and twin stacks beyond a cultivated field

Oil & Gas

Process valves and equipment closures

Monel 400 strip is slit and formed into shims, retaining clips or seal-support pieces around process valves and equipment closures. Thickness, edge finish and bend direction control the finished fit. Utility connections and pressure-boundary parts have separate acceptance requirements on the equipment drawing.

Thickness tolerance · slit edge · rolling direction
Oil & Gas fasteners

Same strip. Different material priorities.

Monel 400 material data
UNS N06625

Inconel 625

Solid-solution strength and resistance to aggressive process liquids.

Connection priority
The stiffness and recovery of the formed strip section
Annealed or solution-annealed 625
The delivery condition affects strength and high-temperature response. Keep the specified condition with the component’s mechanical acceptance; 718-style aging is not the strengthening route for 625. Include liquid retained at slit edges, overlap faces and highly strained bends in the exposure description.
Inconel 625 strip
UNS S32750

Super Duplex 2507

Super-duplex strength and resistance to chloride pitting.

Connection priority
The stiffness and recovery of the formed strip section
Final duplex structure
S32750 chemistry and final solution treatment belong together. Forming, section size and cooling affect the structure represented by the mechanical and corrosion records. Include liquid retained at slit edges, overlap faces and highly strained bends in the exposure description.
Super Duplex 2507 strip
UNS N05500

Monel K-500

Age-hardened strength in the nickel–copper alloy family.

Connection priority
The stiffness and recovery of the formed strip section
Strength and hydrogen exposure
K-500 gains strength through aging. Cathodic protection, hydrogen exposure and the ordered condition need joint consideration in highly loaded marine components. Include liquid retained at slit edges, overlap faces and highly strained bends in the exposure description.
Monel K-500 strip

From drawing to documented delivery

Heat treatment
Heat treatment
CNC machining
CNC machining
Rockwell hardness testing
Rockwell hardness testing
Wooden-crate packing
Wooden-crate packing
  1. 01Drawing & BOMForm, dimensions and quantity
  2. 02Material & formingGrade, heat and manufacturing route
  3. 03Final inspectionGeometry, threads and ordered tests
  4. 04Documents & dispatchLot records and identified packing

Order documents

Material identity
UNS N04400 · heat number · ordered condition
Stock acceptance
Grade chemistry, supplied condition and ordered mechanical requirements.
Dimensional record
Cross-section · Surface · Delivery condition · Heat identity
Traceability
EN 10204 3.1 material certificate · production lot · identified packing

Build your 400 strip enquiry

QUOTE LIST ITEMMonel 400 strip; UNS N04400; Coiled strip

Questions about 400 strip

Why does edge condition belong on a strip order?

A slit edge can become the most highly strained edge during forming. Burr direction, edge finish and the chosen bend radius affect the next operation and the finished contact surface.

Technical references & photo credits