A gripper that drifts off position after a changeover costs a cell far more than its screws. Two causes to check first: a thread in the aluminium plate that has been used too many times, and preload that varies from one changeover to the next.

Engagement in the tapped hole
The Bossard technical guide to engaged thread length gives approximate minimum engagement lengths from practical trials. For screws in structural steel, it gives about 0.9–1.4 times the nominal diameter, depending on the screw property class and thread pitch. For aluminium alloys, it gives roughly 1.0–2.5 times the diameter, depending on the alloy. Those figures apply to M6–M16 steel screws of the listed property classes in cut internal threads with 6g/6H fits and enough wall thickness; some aluminium and class 12.9 combinations have no recommended value, and the guide notes that exact values need a VDI 2230 calculation. For 17-4 PH or titanium screws, or for joints with thread inserts, work the engagement out from the actual strengths and the insert maker's data.
Effective engagement means fully formed thread overlapping on both parts. It does not include:
- the countersink at the hole entry
- the run-out at the end of the screw
- the incomplete thread at the bottom of a blind hole
So a screw sitting 10 mm deep in a hole with a 1 mm countersink and 1.5 mm of tip run-out has about 7.5 mm of effective engagement. State the thread depth, the drill depth and the engagement on the tooling drawing, with the hole material next to them.
For aluminium plates that are opened at every changeover, specify helical inserts or solid thread inserts. A steel thread running in and out of aluminium wears the hole long before the screw.
Key access and the tool envelope
A socket head cap screw is driven from inside its head, so it fits tight tooling where a hex head would need a wrench swing. That only works if the key can reach the socket squarely. For each screw, check:
- head diameter and height against neighbouring walls and parts (ISO 4762 or ASME B18.3 dimensions)
- straight access for the key or bit, and enough length to engage the full socket depth
- whether the screw can be removed without taking off the tool first
Where head height is the limit, a low-head socket screw is an option, stated as its own variant on the drawing.
Choosing the screw
| Candidate | Material and standard | Where it fits end-of-arm tooling | Limit to check |
|---|---|---|---|
| Alloy steel socket head cap screw | Quenched and tempered alloy steel, ASTM A574 or ISO 898-1 class 12.9 | Dry cells with high loads | Rust in humid or washdown cells |
| Stainless A4-80 | 316 family, ISO 4762 / ISO 3506-1 class A4-80 | Most clean, humid and washdown cells | 600 MPa proof; galling; galvanic contact with aluminium when wet |
| 17-4 PH | S17400, ASTM A564, H1025 or H1150 | Wet cells that need more strength than A4-80 | Condition must be stated; cost |
| Titanium Grade 5 | R56400, Ti-6Al-4V | Weight-critical tooling | Galling; cost; galvanic contact with aluminium |
Stainless A4-80 is the common choice for food, pharma and washdown cells. Its 600 MPa minimum proof strength is below that of an alloy steel screw of the same size, so check the clamp load the tool needs.
17-4 PH sits between A4-80 stainless and alloy steel. The ARMCO 17-4 PH product data bulletin gives minimums of 1070 MPa tensile and 1000 MPa yield at H1025, and 930 and 725 MPa at H1150. Material aged at 552°C (H1025) or higher is highly resistant to stress corrosion cracking. Our 17-4 PH socket screws are made in the condition the drawing states.
Titanium Grade 5 saves weight on the arm, which can matter for payload. It galls easily in threads and needs care in assembly.
Any steel or stainless screw in aluminium sets up a galvanic couple. In a dry cell it rarely matters; in a wet or washdown cell, the aluminium around the hole corrodes. A standard metal thread insert does not stop this, because it still conducts; it improves thread strength and life, not galvanic protection. Where the cell is wet, use an insulated insert or another verified isolation method, keep water out of the joint, or let it drain.
Locking, preload and changeovers
Robot motion moves the joint back and forth. Bolt Science's explanation of critical slip shows that a bolt self-loosens when the joint moves far enough sideways to make the head or threads slip; below that distance, it doesn't. The first defence is enough preload and a joint that doesn't slip. Locating pins should take the side loads, not the screws.
State the locking method for each screw on the drawing, for example a threadlocker grade, a locking washer or a prevailing-torque insert, and whether it needs renewing after each removal. Tighten to a written torque with a calibrated driver and keep the lubrication and locking method the same each time; that makes changeovers far more repeatable, though friction still spreads the preload. Where the clamp load is critical, verify the preload rather than relying on torque alone.
Stainless screws in stainless or titanium threads gall readily. Use a thread lubricant if the locking method allows, and replace screws with damaged threads; our note on galling explains the mechanism.
Keep a simple changeover log by tool: which screws were removed, any that turned hard or stripped, and when the inserts were last replaced.
Requesting a quote
List screws by tool, for example: "M6 × 20 socket head cap screws, 17-4 PH H1025, 400 pieces; gripper mounting plate in 6082 aluminium with helical inserts, 9 mm effective engagement; medium-strength threadlocker; removed at weekly changeovers; washdown cell."
Send the tooling drawing and we will quote socket screws in the material and condition it calls for, after checking dimensions and inspection requirements. Locating parts are a separate subject, covered in our guide to 17-4 PH positioning bolts; other automation bolting is on the industrial machinery and automation page.