When an assembly fixture stops repeating after a service, check the positioning bolts as well as the clamps and bushings: a shoulder that is out of tolerance in its final condition gives the same symptom.

Location and retention
A shoulder bolt carries its locating duty on the ground, unthreaded shoulder. The shoulder fits a reamed bore or a bushing and forces the located part back to the same place; the smaller thread below it clamps the stack together. Square-head and other locating bolts work the same way, with a ground diameter or pilot doing the locating.
That gives three separate numbers on the drawing:
- Shoulder diameter and tolerance. ISO 7379 shoulder screws are made with an f9 shoulder, which suits general assembly but is loose for precision location. If the fixture needs a close fit, state a tighter tolerance such as h7 or g6 against the bore.
- Bore. Bore size, tolerance and whether it is reamed, ground or bushed. A shoulder in a drilled hole doesn't locate precisely.
- Shoulder length and datum face. The located part thickness plus any bushing, with an allowance for axial play. If the shoulder is too long, it bottoms out before the datum face seats; if it is too short, the located part rides on the thread.
Final condition: machine, age, then verify
17-4 PH is supplied solution treated (Condition A, at about 1040°C) and machined in that state, then aged to the required strength. The ARMCO 17-4 PH product data bulletin from AK Steel gives the common ageing treatments as 482°C for 1 hour (H900), 552°C for 4 hours (H1025) and 621°C for 4 hours (H1150).
Ageing makes the part contract slightly, and the amount depends on the condition. For a positioning bolt that matters, because a few microns on the shoulder can take it out of an h7 band. The safe sequence is:
- rough machine in Condition A, leaving grinding stock on locating diameters
- age to the specified condition
- finish grind locating diameters and datum faces
- inspect on the aged part
Write on the drawing that locating dimensions apply after final ageing, and ask for the dimensional report on the aged bolts, together with a hardness result (HRC) for the specified condition. A hardness result alone does not establish the complete heat-treatment history.
Choosing the condition and the material
| Candidate | UNS and form | Where it fits a positioning bolt | Limit to check |
|---|---|---|---|
| 17-4 PH, H900 | S17400, bar to ASTM A564 Type 630 | Maximum strength and wear resistance; low-impact fixtures | Low toughness; susceptible to stress corrosion cracking |
| 17-4 PH, H1025 | S17400, ASTM A564 | General fixtures: good strength with better toughness | Hardness lower than H900 |
| 17-4 PH, H1150 | S17400, ASTM A564 | Fixtures with impact or washdown | Lowest strength of the three |
| 316L | S31603, ISO 3506-1 A4-70 or A4-80 | Light-duty locating in washdown or chemical splash | Soft; wears in the bore; galls |
The minimum properties in ASTM A564 for bar are 1310 MPa tensile and 1170 MPa yield at H900, 1070 and 1000 MPa at H1025, and 930 and 725 MPa at H1150. The AK Steel bulletin also notes that H900 is quite susceptible to stress corrosion cracking, while material aged at 552°C (H1025) or above is highly resistant. It recommends caution with H900 where toughness matters.
For a fixture that is clamped repeatedly, sees side loads or is cleaned with water-based coolants and washdown, H1025 or H1150 is usually the safer choice. H900 makes sense where hardness and wear resistance of the locating diameter matter most and the bolt is not impact-loaded. Our guide to 17-4 PH conditions H900 to H1150 compares them in more detail, and 17-4 PH covers the material.
316L doesn't harden by ageing and is too soft for a locating diameter that is used many times, but it can be the right choice for light positioning in heavy washdown.
Wear, cleaning and service records
Each fixture cycle slides the located part on and off the shoulder. Keep the shoulder and bore clean, and lubricate the bore if the process allows; a hardened 17-4 PH shoulder in a soft stainless bushing will scuff the bushing first.
Tighten the thread to a written torque, enough to hold the shoulder against the datum face without stretching the thread.
At each fixture service, record by position:
- shoulder diameter, measured at two points
- wear marks or galling on the shoulder and bore
- any loss of repeatability on the located part
If repeatability falls off in one position only, measure the bore as well as the bolt.
Requesting a quote
Send the bolt drawing with the locating dimensions, for example: "Shoulder bolt, 17-4 PH H1025, shoulder Ø10 h7 × 20, thread M8 × 12, 200 pieces; shoulder ground after ageing; bore Ø10 H7 reamed; dimensional report on aged parts."
From the drawing we confirm the condition, grinding sequence and inspection, then quote 17-4 PH socket screws, square-head positioning bolts or a custom locating bolt. Bolts for hot tooling are a different problem, covered in our guide to A-286 long-shank bolts in heated tooling; fixture and automation bolting in general is on the industrial machinery and automation page.