Monel K-500 Hex socket countersunk screws
ISO 10642ASTM B865
Flush seating puts the load into the conical head of a Monel K-500 countersunk screw. Age-hardened strength in the nickel–copper alloy family is combined with a matching head angle and acceptance of the reduced head section.
- MOQ
- 100PCS
- Samples · typical
- ~20 days
- Production · typical
- 25–35 days
- Heat treatment
- Annealed / age hardened
EN 10204 3.1 MTC + heat-number traceability
Which standard is on your order?
Raw Material Specifications
Finished-Screw Specifications
Threads · Metric
Threads · Inch
Dimension Reference
Heat Treatment
Annealed or age hardenedAnnealing provides a workable starting condition, while controlled aging develops the higher strength specified for age-hardened K-500.
What we can make in Monel K-500
Head angle & seating
90° metric and 82° inch heads need matching countersinks. Head diameter and recess depth control whether the screw sits flush.
Socket & overall length
Specify overall length including the head. Socket size and depth govern key engagement, especially in shallow head sections.
Reduced head loadability
ISO 10642 identifies reduced loadability from the countersunk head and socket geometry. For Inconel 718 or A-286, assess head capacity and seating contact alongside the specified material strength and assembly preload.
- Drive
- Internal hex socket
- Head angle
- 90° metric · 82° inch
- Length basis
- Overall, including head
- Threads
- Metric · UNC · UNF · UNJ
- Final condition
- Annealed · age hardened
- Inspection
- Head angle & diameter · Socket size & depth · Overall length · Thread gauges
Manufacturing route
CNC machining suits samples and small batches. Volume heads are formed in a workable condition with the final aging route included in process planning.
Heat treatment & final condition
Solution treatment and the specified aging condition are recorded against the production lot; final dimensions are checked after thermal processing.
Finished geometry
Head angle, socket depth and the head-to-shank transition are inspected with the thread; the reduced head section remains part of finished-part acceptance.
Where K-500 fits — and what matters

Offshore & Marine
Marine equipment enclosuresMonel K-500 hex socket countersunk screws secure marine equipment enclosures with the head below or flush with the surface, leaving clearance for neighbouring moving parts or removable covers. The assembled contact is exposed to saltwater, deposits and neighbouring metals.

Water Treatment & Desalination
Filtration-equipment coversMonel K-500 hex socket countersunk screws secure filtration-equipment covers with the head below or flush with the surface, leaving clearance for neighbouring moving parts or removable covers. The water stream, cleaning cycle and retained liquid define exposure at the installed part.

Oil & Gas
Instrument and auxiliary-equipment enclosuresMonel K-500 hex socket countersunk screws secure instrument and auxiliary-equipment enclosures with the head below or flush with the surface, leaving clearance for neighbouring moving parts or removable covers. Utility connections and pressure-boundary parts have separate acceptance requirements on the equipment drawing.
Same hex socket countersunk screw. Different material priorities.
Monel K-500 material dataInconel 625
Solid-solution strength and resistance to aggressive process liquids.
- Connection priority
- Head-bearing stress in the reduced countersunk section
- Annealed or solution-annealed 625
- The delivery condition affects strength and high-temperature response. Keep the specified condition with the component’s mechanical acceptance; 718-style aging is not the strengthening route for 625. Include liquid retained at the conical seat and recessed socket in the exposure description.
Super Duplex 2507
Super-duplex strength and resistance to chloride pitting.
- Connection priority
- Head-bearing stress in the reduced countersunk section
- Final duplex structure
- S32750 chemistry and final solution treatment belong together. Forming, section size and cooling affect the structure represented by the mechanical and corrosion records. Include liquid retained at the conical seat and recessed socket in the exposure description.
Duplex 2205
Duplex strength and chloride-corrosion resistance.
- Connection priority
- Head-bearing stress in the reduced countersunk section
- S31803 or S32205
- The specified UNS fixes the chemistry. Solution treatment, section size and the ordered mechanical or corrosion tests establish the final duplex condition. Include liquid retained at the conical seat and recessed socket in the exposure description.
From drawing to documented delivery




- 01Drawing & BOMForm, dimensions and quantity
- 02Material & formingGrade, heat and manufacturing route
- 03Final inspectionGeometry, threads and ordered tests
- 04Documents & dispatchLot records and identified packing
Order documents
- Material identity
- UNS N05500 · heat number · ordered condition
- Final-part acceptance
- Lot-linked aging record and mechanical acceptance in the final condition.
- Dimensional record
- Head angle & diameter · Socket size & depth · Overall length · Thread gauges
- Traceability
- EN 10204 3.1 material certificate · production lot · identified packing